Configuration/Setup
R&S FSMR
1166.3363.12
4.19-2
E-2
•
The
TRANSDUCER
softkey opens a submenu for entering the correction characteristics for
transducers.
•
The
GENERAL SETUP
softkey opens a submenu for all the general settings such as IEC/IEEE-bus
address, date and time as well as the configuration of the device interfaces.
FIRMWARE OPTIONS
can be installed under this menu item.
•
The
SYSTEM INFO
softkey opens a submenu for displaying the hardware configuration of the
instrument, the switching cycle statistics and system messages.
•
The
SERVICE
softkey opens a submenu in which special device functions and system information
can be selected for servicing. The password required for service functions can be entered in this
submenu.
•
The
IF SHIFT
softkey opens a submenu to activate or deactivate 1st IF shifting.
•
The
RECEIVER PRESET
softkey sets the receiver mode as preset mode.
•
The
ANALYZER PRESET
softkey sets the analyzer mode as preset mode.
External Reference
The R&S FSMR can use the internal reference source or an external reference source as frequency
standard from which all internal oscillators are derived. A 10 MHz crystal oscillator is used as internal
reference source. In the default setting (internal reference), this frequency is available as output signal
at rear-panel connector REF OUT, e.g. to synchronize other instruments to the reference of the R&S
FSMR.
In the setting
REFERENCE EXT
, the connector REF IN is used as input connector for an external
frequency standard. In this case all internal oscillators of the R&S FSMR are synchronized to the
external reference frequency (also 10 MHz).
SETUP
menu:
REFERENCE
INT EXT
The
REFERENCE INT / EXT
softkey switches between the internal and
external reference.
If the external reference is selected, also the frequency of the external
reference is adjustable between 1 MHz and 20 MHz.
The default value is 10 MHz.
These reference settings are not changed if a preset occurs to maintain the
specific setup of a test system.
If the reference signal is missing when switching to external reference, the
message "EXREF" appears after a while to indicate that there is no
synchronization.
On switching to internal reference please ensure that the external reference signal
is de-activated to avoid interactions with the internal reference signal.
IEC/IEEE-bus command:
ROSC:SOUR INT
ROSC:EXT:FREQ <numeric value>
External Noise Source
SETUP
menu:
NOISE SRC
ON OFF
The
NOISE SRC ON/OFF
softkey switches on or off the supply voltage for an
external noise source which is connected to the
NOISE SOURCE
connector
on the rear panel of the instrument.
IEC/IEEE-bus command:
DIAG:SERV:NSO ON
Summary of Contents for FSMR
Page 1: ...R S FSMR Measuring Receiver Operating Manual Test Measurement Operating Manual 1313 9723 12 01...
Page 4: ......
Page 22: ......
Page 26: ...Contents Preparing for Operation R S FSMR 1155 5047 12 I 1 2 E 2 Fig 1 1 Front View...
Page 28: ...Front View R S FSMR 1166 3363 12 1 2 E 2 Fig 1 1 Front View...
Page 30: ...Front View R S FSMR 1166 3363 12 1 4 E 2 Fig 1 1 Front View...
Page 32: ...Front View R S FSMR 1166 3363 12 1 6 E 2 Fig 1 1 Front View...
Page 34: ...Front View R S FSMR 1166 3363 12 1 8 E 2 Fig 1 1 Front View...
Page 66: ......
Page 86: ......
Page 130: ...Menu Overview R S FSMR 1166 3363 12 3 42 E 3 Menu Overview another Keys MKR Key...
Page 141: ...R S FSMR Menu Overview 1166 3363 12 3 53 E 3 LOCAL Menu LOCAL...
Page 144: ......
Page 150: ......
Page 156: ......
Page 202: ......
Page 208: ......
Page 216: ......
Page 230: ......
Page 254: ......
Page 280: ......
Page 348: ......
Page 376: ...Configuration Setup R S FSMR 1166 3363 12 4 19 28 E 2...
Page 390: ......
Page 408: ......
Page 428: ......
Page 446: ......
Page 536: ......
Page 799: ......
Page 921: ......
Page 935: ......
Page 937: ...Contents Error Messages R S FSMR 1166 3363 12 I 9 2 E 1...