R&S FSMR
CALCulate Subsystem
1313.9723.12
6.1-49
E-1
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:CSTep
This command sets the step width of the center frequency in the selected measurement window to
the X value of the current marker. If marker 2, 3 or 4 is selected and used as delta marker, it is
switched to the marker mode.
Example:
"
CALC2:MARK3:FUNC:CST"
'Sets the center frequency of screen B to the
'same value as the frequency of marker 3.
Characteristics:
*RST value:
-
SCPI:
device-specific
This command is an event and therefore has no *RST value and no query.
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:DEModulation:CONTinuous
ON | OFF
This command switches on or off the continuous demodulation in the frequency domain (span >0) in
the selected measurement window. Thus acoustic monitoring of the signals can be performed in the
frequency domain. The function does not depend on the selected marker, i.e. the numeric suffix <1
to 4> is irrelevant.
Example:
"CALC2:MARK3:FUNC:DEM:CONT ON"
'Switches on the continuous
'demodulation in screen B.
Characteristics:
*RST value:
OFF
SCPI:
device-specific
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:DEModulation:HOLDoff
10ms to 1000s
This command defines the hold time at the marker position for the demodulation in the frequency
domain (span > 0). The setting is independent of the measurement window and the selected marker,
i.e. the suffixes <1|2> and <1 to 4> are irrelevant
Example:
"
CALC:MARK:FUNC:DEM:HOLD 3s"
Characteristics:
*RST value:
- (DEModulation is set to OFF)
SCPI:
device-specific
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:DEModulation:SELect
AM | FM
This command selects the demodulation type for the audio demodulator. The command is
independent of the measurement window and of the selected marker, i.e. suffixes 1|2 and 1 to 4 are
irrelevant.
Example:
"
CALC:MARK:FUNC:DEM:SEL FM"
Characteristics:
*RST value:
AM
SCPI:
device-specific
CALCulate<1|2>:MARKer<1 to 4>:FUNCtion:DEModulation:SQUelch:LEVel
0 to 100 PCT
This command sets the trigger level for the squelch function.
Example:
"CALC:MARK:FUNC:DEM:SQU:LEV 80 PCT"
Characteristics:
*RST value: 50PTC
SCPI:
device-specific
Summary of Contents for FSMR
Page 1: ...R S FSMR Measuring Receiver Operating Manual Test Measurement Operating Manual 1313 9723 12 01...
Page 4: ......
Page 22: ......
Page 26: ...Contents Preparing for Operation R S FSMR 1155 5047 12 I 1 2 E 2 Fig 1 1 Front View...
Page 28: ...Front View R S FSMR 1166 3363 12 1 2 E 2 Fig 1 1 Front View...
Page 30: ...Front View R S FSMR 1166 3363 12 1 4 E 2 Fig 1 1 Front View...
Page 32: ...Front View R S FSMR 1166 3363 12 1 6 E 2 Fig 1 1 Front View...
Page 34: ...Front View R S FSMR 1166 3363 12 1 8 E 2 Fig 1 1 Front View...
Page 66: ......
Page 86: ......
Page 130: ...Menu Overview R S FSMR 1166 3363 12 3 42 E 3 Menu Overview another Keys MKR Key...
Page 141: ...R S FSMR Menu Overview 1166 3363 12 3 53 E 3 LOCAL Menu LOCAL...
Page 144: ......
Page 150: ......
Page 156: ......
Page 202: ......
Page 208: ......
Page 216: ......
Page 230: ......
Page 254: ......
Page 280: ......
Page 348: ......
Page 376: ...Configuration Setup R S FSMR 1166 3363 12 4 19 28 E 2...
Page 390: ......
Page 408: ......
Page 428: ......
Page 446: ......
Page 536: ......
Page 799: ......
Page 921: ......
Page 935: ......
Page 937: ...Contents Error Messages R S FSMR 1166 3363 12 I 9 2 E 1...