Recalling Data Sets
R&S FSMR
1313.9617.12
4.20-8
E-1
The
EDIT FILE NAME
softkey sets the focus on the File Name field and.
In the Save dialog box, the field already contains a suggestion for a new name: the
file name used in the last saving process is counted up to the next unused name.
For example, if the name last used was "test_004", the new name "test_005" is
suggested, but only if this name is not in use. If the name "test_005" is already in
use, the next free name is suggested, e.g. "test_006". You can change the
suggested name to any name conform to the following naming conventions.
The name of a settings file consists of a base name followed by an underscore and
three numbers, e.g. "limit_lines_005". In the example, the base name is
"limit_lines".
The base name can contain characters, numbers and underscores. The file
extension is added automatically and can not be changed.
The
EDIT COMMENT
softkey activates the entry of commentary concerning the
current data set. The focus is set on the Comment field and an on-screen
keyboard opens.
SELECT
ITEMS
The
SELECT ITEMS
softkey moves the selection bar to the first line, left column of
the
Items
field. An entry is selected. Position the entry focus to the corresponding
partial data set using the cursor keys and then press the
ENTER
key in the desired
line. The selection is cleared by pressing the key again.
IEC/IEEE command:
Current Settings:
MMEM:SEL:HWS ON
All Limit Lines:
MMEM:SEL:LIN:ALL ON
All Traces:
MMEM:SEL:TRAC ON
Source Cal Data:
MMEM:SEL:SCD ON
Note that the command MMEM:SEL:SCD ON (Source Cal Data) is only
availablewith option R&S FSU-B09 or R&S FSU-B10.
The Dialog
Save
table offers the following selectable data subsets in the
Items
field:
Current Settings
These settings include:
•
current configuration of general instrument parameters
•
current measurement hardware settings
•
active limit lines:
A data set may contain maximum 8 limit lines for each window.
It always contain the activated limit lines and the de-activated
limit lines used last, if any.
Consequently, the combination of the restored de-activated limit
lines depends on the sequence of use with command
MMEM:LOAD
.
•
the activated transducer factor
•
user-defined colour settings
•
configuration for hardcopy output
•
settings of tracking generator (only with option tracking
generator)
•
settings of tracking generator (only with option)
All Limit Lines
all limit lines
All Transducer
all transducer factors
All Traces
all traces which are not blanked
Source Cal Data
correction data for tracking generator (only with options B9 / B10)
Summary of Contents for FSMR
Page 1: ...R S FSMR Measuring Receiver Operating Manual Test Measurement Operating Manual 1313 9723 12 01...
Page 4: ......
Page 22: ......
Page 26: ...Contents Preparing for Operation R S FSMR 1155 5047 12 I 1 2 E 2 Fig 1 1 Front View...
Page 28: ...Front View R S FSMR 1166 3363 12 1 2 E 2 Fig 1 1 Front View...
Page 30: ...Front View R S FSMR 1166 3363 12 1 4 E 2 Fig 1 1 Front View...
Page 32: ...Front View R S FSMR 1166 3363 12 1 6 E 2 Fig 1 1 Front View...
Page 34: ...Front View R S FSMR 1166 3363 12 1 8 E 2 Fig 1 1 Front View...
Page 66: ......
Page 86: ......
Page 130: ...Menu Overview R S FSMR 1166 3363 12 3 42 E 3 Menu Overview another Keys MKR Key...
Page 141: ...R S FSMR Menu Overview 1166 3363 12 3 53 E 3 LOCAL Menu LOCAL...
Page 144: ......
Page 150: ......
Page 156: ......
Page 202: ......
Page 208: ......
Page 216: ......
Page 230: ......
Page 254: ......
Page 280: ......
Page 348: ......
Page 376: ...Configuration Setup R S FSMR 1166 3363 12 4 19 28 E 2...
Page 390: ......
Page 408: ......
Page 428: ......
Page 446: ......
Page 536: ......
Page 799: ......
Page 921: ......
Page 935: ......
Page 937: ...Contents Error Messages R S FSMR 1166 3363 12 I 9 2 E 1...