Alarm
Cause
Level
E1 LOF
Data sent by the upstream node is incorrect,
because services are configured improperly or the
hardware fails.
Critical
E1 CRC
An Error on data during transmission.
Critical
E1 GID ERROR
Reverse multiplexing configurations are
incorrect.
Critical
E1 remote alarms (AIS,
LOF, CRC, and LOS)
The remote device managed by the card generates
(AIS, LOF, CRC, and LOS) alarms.
Critical
E1 remote loopback
alarm
The remote device managed by the card generates
a loopback.
Critical
Ethernet interface Link
Down
Links of Ethernet interfaces are disconnected.
Critical
13.2.6 Specifications
Table 13-11 lists specifications of the OPCOM3500E-EOP3FE.
Table 13-11
Specifications of the OPCOM3500E-EOP3FE
Parameter
Value
Dimensions
25 mm (width) × 232 mm (depth) × 240 mm (height)
Weight
< 0.5 kg
Max. power consumption 20 W