46
Chapter 3
Administrative Tasks
To re-initialize generator through system reset:
1. Hold down ACS and DSS while powering up the generator.
A confirmation message is displayed.
2. Press the Outputs key to continue, or press the Step key to cancel the operation.
To re-initialize and calibrate the generator using command interface:
1. Establish a terminal session with the generator (see page 14).
2. Enter the following command:
INIT
The generator then goes through a complete self-test and self-calibration procedure.
To re-initialize without calibrating the generator using the command line:
1. Establish a terminal session with the generator (see page 14).
2. Enter the following command:
BOIT
The generator is re-intialized.