802BT/802R Video Test Generator User Guide
131
To view specific timing information of an external HDMI/DVI source signal:
1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator.
2. Using a terminal emulator, establish a terminal connection with the generator. Refer to
“
Setting up a terminal connection with the generator
” on page 14.
3. Enter the following commands to configure the generator to output a digital signal
(HDMI or DVI):
SROP
2 4
This removes analog friendly mode and configures the generator to output either a DVI
or HDMI signal depending on the interface hardware the generator is equipped with
(DVI or HDMI).
4. (optional) Enter the following command to set the status display mode:
SROP 8
5. Enter the following commands to initiate the measurement of timing parameters.
PNSF
1
// selects the source of timing information as “Measured”
TMAU
// initiates measurement of timing from external source
HTOT
?
// queries for the horizontal total pixels
HRES
?
// queries for the horizontal active pixels
See page 548 for additional parameters you can query.
Summary of Contents for 802BT
Page 1: ...802BT 802R Video Test Generator User Guide ...
Page 52: ...42 Chapter 2 Testing Video Displays ...
Page 62: ...52 Chapter 3 Administrative Tasks ...
Page 118: ...108 Chapter 7 Using GPIB Interface ...
Page 194: ...184 Chapter 10 Testing EDID ...
Page 204: ...194 Chapter 11 Testing HDCP ...
Page 214: ...204 Appendix A Command Reference Commands by name ...
Page 595: ...Video Test Generator User Guide 585 ...
Page 611: ...Video Test Generator User Guide 601 ...
Page 612: ...602 Appendix A Command Reference ...
Page 716: ...706 Appendix B Image Reference ...
Page 744: ...734 Appendix C Error Messages ...