488
Appendix A
Command Reference
PSPM
Probe Sync Pulse Mode
Class
Special Sync Probe Pulse
Description
Determines what lines in the frame or field the probe pulse occurs on the special sync
output. The PSPM? query returns the current PSPM value.
Command syntax
PSPM
mode
mode integer
0 = once per frame
1 = every active line in frame
3 = every line in frame
Query syntax
PSPM?
Query response
0, 1, or 3
Other required
commands
The
FMTU
command instructs the generator to use the new settings. The
ALLU
command
updates the hardware to the new settings and redraws the test image.
Related commands
PSPG
,
PSPP
,
PSPW
,
PSHD
,
PSVD
Example
PSPG 1
// Enables probe pulse on special sync
PSPP 1
// Sets probe pulse polarity to positive
PSPW 10
// Sets probe pulse width to 10 pixels
PSHD 200
// Sets probe pulse horizontal delay to 200 pixels
PSVD 300
// Sets probe pulse vertical delay to 300 pixels
PSPM 1
// Sets probe pulse to occur on each active line in a frame
ALLU
// Applies the settings
Summary of Contents for 802BT
Page 1: ...802BT 802R Video Test Generator User Guide ...
Page 52: ...42 Chapter 2 Testing Video Displays ...
Page 62: ...52 Chapter 3 Administrative Tasks ...
Page 118: ...108 Chapter 7 Using GPIB Interface ...
Page 194: ...184 Chapter 10 Testing EDID ...
Page 204: ...194 Chapter 11 Testing HDCP ...
Page 214: ...204 Appendix A Command Reference Commands by name ...
Page 595: ...Video Test Generator User Guide 585 ...
Page 611: ...Video Test Generator User Guide 601 ...
Page 612: ...602 Appendix A Command Reference ...
Page 716: ...706 Appendix B Image Reference ...
Page 744: ...734 Appendix C Error Messages ...