354
Appendix A
Command Reference
GNPT?
Get Number of Pixel Tested
Class
Signal analyzer - Pixel data
Description
Returns the number of pixels being measured in billions after a pseudo noise
measurement has finished execution (that is, completed the PNAU command).
Query syntax
GNPT?
Query response
number of pixels
Example
PNAU //Pseudo-random noise generated
CR //Stop pseudo-random noise
GNPT? //Returns 4.255 billion pixels
4.255
Related commands