HSPP
Horizontal Sync Pulse Polarity
Class
Format parameter setting - Synchronization
Description
Establishes the logic sense of the digital horizontal sync outputs. Setting polarity to 1
causes the leading edge of horizontal sync to be a low-to-high transition. Setting polarity to
0 causes the leading edge of horizontal sync to be a high-to-low transition. The HSPP?
query returns the current polarity of HSPP.
Command syntax
HSPP
polarity
polarity
0 = active-low (negative going pulse)
1 = active-high (positive going pulse)
Query syntax
HSPP?
Query response
0 or 1
Other required
commands
To use digital horizontal sync, it must be gated on with the
HSPG
command and digital
separate H and V sync must be selected with the
SSST
command. The
FMTU
command
instructs the generator to use the new settings. The
ALLU
command updates the
hardware to the new settings and redraws the test image.
Example
HSPP 0 // Set active low H sync in buffer
HSPG 1 // Enable H sync output in buffer
SSST 1 // Select H&V sync type in buffer
FMTU
// Update hardware to current buffer contents
Summary of Contents for 802BT
Page 1: ...802BT 802R Video Test Generator User Guide ...
Page 52: ...42 Chapter 2 Testing Video Displays ...
Page 62: ...52 Chapter 3 Administrative Tasks ...
Page 118: ...108 Chapter 7 Using GPIB Interface ...
Page 194: ...184 Chapter 10 Testing EDID ...
Page 204: ...194 Chapter 11 Testing HDCP ...
Page 214: ...204 Appendix A Command Reference Commands by name ...
Page 595: ...Video Test Generator User Guide 585 ...
Page 611: ...Video Test Generator User Guide 601 ...
Page 612: ...602 Appendix A Command Reference ...
Page 716: ...706 Appendix B Image Reference ...
Page 744: ...734 Appendix C Error Messages ...