802BT/802R Video Test Generator User Guide
169
4. Using the
Image
knob, select the ON setting to enable analyzer images.
5. Using the
Format
knob, select the
Auto Based On
field.
6. Using the
Image
knob, select CURRENT in the highlighted field to measure the
HDMI/DVI signal originating
internally
from the generator.
7. Press and release the
Step
key to save the currently displayed parameters.
The light on the
Step
key extinguishes, and the new settings are implemented for
analyzer mode operation.
To configure the analyzer to emulate the EDID structure of a display:
1. Determine the HDMI/DVI display you wish to emulate and if possible obtain a text file
of its EDID.
Note: This can be obtained from the manufacturer or by reading the EDID using the
HDMI/DVI generator. For procedures on reading the EDID of a display with the
generator, please refer to “
Viewing EDID from a display
” on page 171.
2. Connect an HDMI/DVI cable between the HDMI/DVI Tx and Rx connectors on the
generator.
3. Using a terminal emulator, establish a terminal session with the generator (see page
14).
4. Modify the EDID structure in the generator using the
XDID
and
DIDU
commands.
For example, to change the color characteristics of the EDID structure (a total of 10
bytes starting at byte 19), you could use the following command strings:
XDID 19 A E88A82A0564796240F48
DIDU
To program multiple segments (or the entire EDID structure) at once, create a text file
containing the EDID. Then send the text file to the generator using your terminal
emulator’s file transfer feature.
The following commands write the entire EDID block 0:
XDID 0 80 00FFFFFFFFFFFF005A63118F01010101130D010380221B782A4706A55C47
9C251E4F54BFEF008180310A010101010101010101010101302A009851002A40307013
00520E1100001E000000FF004132333033313931353335390A000000FD00324B1E530E
000A202020202020000000FC0056583730302D330A20202020200095
DIDU
5. To verify the EDID structure, use the
EDID?
query. This command will display the entire
EDID structure in ASCII hex format.
To view a specific segment of EDID, use the
I2CR?
query. This command will display
the requested EDID in ASCII hex format.
6. If desired, use the
STRG
command to stretch the SCL low signal for 5 ms in the
analyzer’s receiver.
Summary of Contents for 802BT
Page 1: ...802BT 802R Video Test Generator User Guide ...
Page 52: ...42 Chapter 2 Testing Video Displays ...
Page 62: ...52 Chapter 3 Administrative Tasks ...
Page 118: ...108 Chapter 7 Using GPIB Interface ...
Page 194: ...184 Chapter 10 Testing EDID ...
Page 204: ...194 Chapter 11 Testing HDCP ...
Page 214: ...204 Appendix A Command Reference Commands by name ...
Page 595: ...Video Test Generator User Guide 585 ...
Page 611: ...Video Test Generator User Guide 601 ...
Page 612: ...602 Appendix A Command Reference ...
Page 716: ...706 Appendix B Image Reference ...
Page 744: ...734 Appendix C Error Messages ...