Video Test Generator User Guide
529
SMOD
Sequence operating MODe
Class
Sequence editor control
Description
Sets the sequence mode. The SMOD? query returns the current setting of SMOD.
Command syntax
SMOD
mode
mode
0 = disable
1 = enable manual step mode that stops at last step
2 = enable manual step mode that wraps to first step after last step
3 = enable continuous auto stepping
Query syntax
SMOD?
Query response
mode
Other required
commands
The
SEQL
command loads the sequence and
SEQU
starts to run it.
Example
SEQL MY_SEQ // Load "MY_SEQ" in edit buffer
SEQU
// Start running the sequence in the buffer
SMOD 3