464
Appendix A
Command Reference
PCPG
Pixel Clock Pulse Gate
Class
Format parameter settings
Description
Enables and disables the pixel clock pulse output on generators that have a pixel clock
output available. The PCPG? query returns the current setting of PCPG.
Command syntax
PCPG
mode
mode
0 = OFF
1 = ON
Query syntax
PCPG?
Query response
mode
Other required
commands
FMTU
or
ALLU
Example
PCPG 1 // Enable pixel clk output in buffer
FMTU
// Update hardware with format data