Video Test Generator User Guide
553
UIDN
User IDeNtification
Class
System parameter settings
Description
Sets up the text string that is placed in the upper portions of the SMPTE133 and Cubes
images. The command can be used to add a company name or other identification to the
images. The command will not change the text in a currently displayed image; it must be
redrawn to use the new text. The factory default string is “Quantum Data.” The UIDN?
query returns the current text string.
Command syntax
UIDN
string
string
text string 80 characters in length
Query syntax
UIDN?
Query response
string
Other required
commands
The
IMGU
command redraws the last selected test image. The
ALLU
command updates
hardware to the new setting and redraws the test image.
Example
UIDN "XYZ Monitor Mfg." // Change text string
IMGL SMPTE133
// Select image that uses the text string
IMGU
// Draw the image using new string