
Video Test Generator User Guide
491
PSVD
Probe Sync Pulse Vertical Delay
Class
Special Sync Probe Pulse
Description
Sets the line in the frame or field that the probe pulse occurs on the special sync output.
The PSVD? query returns the current PSVD value.
Command syntax
PSVD
line
line integer
0 = PSVD(VTOT-1)
Query syntax
PSVD?
Query response
line
Other required
commands
The
FMTU
command instructs the generator to use the new settings. The
ALLU
command
updates the hardware to the new settings and redraws the test image.
Related commands
PSPG
,
PSPW
,
PSPP
,
PSHD
,
PSPM
Example
PSPG 1
// Enables probe pulse on special sync
PSPP 1
// Sets probe pulse polarity to positive
PSPW 10
// Sets probe pulse width to 10 pixels
PSVD 300
// Sets probe pulse vertical delay to 300 pixels
ALLU
// Applies the settings
Summary of Contents for 802BT
Page 1: ...802BT 802R Video Test Generator User Guide ...
Page 52: ...42 Chapter 2 Testing Video Displays ...
Page 62: ...52 Chapter 3 Administrative Tasks ...
Page 118: ...108 Chapter 7 Using GPIB Interface ...
Page 194: ...184 Chapter 10 Testing EDID ...
Page 204: ...194 Chapter 11 Testing HDCP ...
Page 214: ...204 Appendix A Command Reference Commands by name ...
Page 595: ...Video Test Generator User Guide 585 ...
Page 611: ...Video Test Generator User Guide 601 ...
Page 612: ...602 Appendix A Command Reference ...
Page 716: ...706 Appendix B Image Reference ...
Page 744: ...734 Appendix C Error Messages ...