VIBSCANNER 11.2010
41
Adaptive measurement task
(only for characteristic overall values)
In ‘adaptive measurement tasks’ a further diagnostic mea-
surement starts automatically when a limit has been
exceeded. In this way, the sequence of the route adapts
itself to the local machine status (‘adaptive’). This diagno-
stic measurement may be a spectrum or further characteris-
tic overall value and was defined in the OMNITREND
software.
The limit that triggers the diagnostic measurement
(prewarning, warning, alarm), is defined as an 'adap-
tive trigger' in the OMNITREND software.
If no 'adaptive trigger' is defined, the diagnostic mea-
surement is triggered when the smallest limit is ex-
ceeded.
Adaptive measurement tasks are marked by an arrow in the
task screen:
Route
Note
The stored diagnostic measurement task can be displayed
by clicking on ‘Adapt’ (Adaptive) in the menu. To hide the
task, click again on ‘Adapt’.
Adaptive task
Diagnostic task (spectrum)