VIBSCANNER 11.2010
35
Trend
The development of the machine condition can be recorded
and documented with the aid of a trend measurement. In
this case, characteristic values are always regularly record-
ed at the same measurement location under the same
conditions. The results are saved in a file.
Trend display
• Mark a measurement task in the selection screen (
Σ
1,
Σ
2), and click on ‘File’ in the menu to open the file
manager (see Note, page 27):
• Click on the file containing the trend data:
‘File Manager’
(see page 64)
The status line displays the measured value as well as the
date and time of the highlighted measurement.
Joystick functions:
Right/ left:
Move the cursor along the trend curve
Top/ bottom: Display trend for RMS, 0-p, p-p
Double-click: Start a new measurement
Single-click: Zoom the trend curve (see next page)
Limit for
‘Alarm’
‘Warning’
‘Prewarning’
Multimeter