VIBSCANNER 11.2010
58
Transducer
Before the measurement, you must check the transducer
selected in the transducer setup and, if necessary, change
it.
VIBSCANNER automatically recognizes the transducer
connected to the blue analog socket. If another trans-
ducer type is selected in the transducer setup, the
measurement is not performed. Also in the case of
short-circuit or open line, VIBSCANNER does not start
the measurement.
VIBSCANNER only displays those transducers for se-
lection that have parameters that conform with the
settings in the ‘measurement’ setup.
Check that the transducer (or a compatible type) is
entered and selected in the instrument setup as an
‘available transducer’ (page 21).
Connecting an
external transducer
Note
Transducers
External vibration transducers
... are required for vibration measurements on
– low-speed machines (< 10 Hz / < 600 min.
-1
)
– measurement locations that are difficult to access
– permanently-installed measurement locations
– VIBCODE measurement locations
– ...
Connect the transducer cable to the socket marked in blue.
For correct orientation, line up the red point on the plug
with the point on the socket: