![PRIMERGY BX620 S2 User Manual Download Page 34](http://html.mh-extra.com/html/primergy/bx620-s2/bx620-s2_user-manual_1601715034.webp)
34
Chapter 2 Checking before OS Installation
●
Using a CD-ROM / DVD-ROM Drive for USB (Change of Device Priority
Sequence)
When using the CD-ROM or DVD-ROM for USB, change the device priority sequence in the [Boot]
menu of the BIOS Setup Utility.
For more details about changing the boot drive, refer to "8.2.13 Boot Device Priority Submenu"
●
Performing Remote Installation
Before performing remote installation of ServerStart, use the following procedures to enable network
startup (PXE). In addition, check the MAC address.
When booting the server blade with PXE, turn on the server blade power one minute or more after the
main power of the chassis was turned on. Turning on the server blade power just after the main power
was turned on may cause PXE not to boot due to the Switch Blade not having been started.
The PXE boot function is not available for the LAN port of the 1 Gbit/s Ethernet I/O Module.
1
Take the following steps in the BIOS Setup Utility.
Set PXE (IBA CE slot nnnn v) to the highest level in the boot priority sequence.
For more details about changing the boot drive, refer to "8.2.13 Boot Device Priority Submenu"
The boot priority sequence can be changed from Web UI or CLI for the Management Blade.
Refer to "BX600 Management Blade Hardware Guide".
2
Check the MAC address.
After BIOS setup, start up the server from the network.
After POST was completed, the MAC address is displayed as shown below.
The MAC address is required for remote installation. Write it down.
3
Turn off the server.
You can confirm that the server is turned off using "Deployment Parameter" for Web UI and
CLI, and "Server Blade MAC Address Table" for CLI of the Management Blades. For details,
refer to "BX600 Management Blade Hardware Guide".
1st Boot Device [Y-E USB-FDU]
2nd Boot Device [CENERIC CDR****](
3rd Boot Device [#520 ID00 LUN0 ***] (When an expansion card slot
module is not installed)
4th Boot Device [IBA CE Slot **** v]
5th Boot Device [IBA CE Slot **** v]
CLIENT MAC ADDR: ** ** ** ** ** **