242
Chapter 9 Operation and Maintenance
●
The server blade is not turned on, or the KVM select LED blinks
Check whether the number of installed server blades exceeds the limit.
For details, refer to "Chapter 4.2 Installing Server Blades" in "BX600 S2 Blade Server System Unit
Hardware Guide"
●
The hard disk access LED does not light up
The server blade may be damaged. Contact an office listed in the "Contact Information" of "Start
Guide".
When contacting an office listed in the "Contact Information" of "Start Guide", refer to "9.9.1
pg.274) and collect the required information.
●
An error message is displayed
Refer to "9.2.2 Error Messages" (
●
The LAN does not operate properly
The Switch Blade may not be running properly. Check the Switch Blade settings.
■
Switch Blade
If there is a problem on the connection with network, first check the wiring, and confirm that the device
is normally connected to network.
If the error still occurs, refer to the following.
●
Diagnosis of switch indicator
There is a device connected to a port of the Switch Blade, but the link LED is
off
• Check that the Switch Blade and connected device are turned on.
• Check that the cable is connected to both the Switch Blade and device.
• Check that the cable type is appropriate and the cable length does not exceed the allowable range.
• Check that there is no defect in the connection between the cable and adapter of the connected
device. Replace the defective cable or adapter as required.
• Check that all the system components are installed correctly. If the network cable does not normally
function, execute a test in the environment where all the components other than the cable normally
function.