Floppy Disk Drive
●
Cannot read or write to the floppy disk.
Prolonged use of the floppy disk drive accumulates dust on the device head (the part which reads/writes
data). A dirty head can impair the ability to read/write data to/from a floppy disk correctly. Clean the
head once every three months.
●
Cannot write to the floppy disk.
• Check to see whether the floppy disk drive is properly connected to the server blade.
For more information on the connection procedure, refer to "Start Guide".
• The write protection of the floppy disk may be applied.
Flip the switch on the disk to allow writing.
■
CD-ROM Drive
●
Cannot read data.
• Check to see whether the CD-ROM drive is properly connected to the server blade.
For more information on the connection procedure, refer to "Start Guide".
• The CD-ROM drive may not properly be recognized on the OS. Check the settings.
For details, refer to the manual supplied with the CD-ROM drive.
• Check to see whether the CD-ROM is inserted properly. If it is not, correctly insert the CD-ROM so
that the label is facing up.
• Check to see that the CD-ROM is not dirty. If it is dirty, wipe it with a soft, dry cloth.
• Check to see that the CD-ROM is not scratched or bent. If scratched or damaged, replace the CD-
ROM.
●
The unit does not operate properly.
• Check to see whether the cable is connected properly. If it is not, correctly connect the cable.
For more information on the connection procedure, refer to "Start Guide" and the manual supplied
with the CD-ROM drive.
■
SCSI Device (Internal/External)
●
The unit does not operate properly.
• Check to see whether the SCSI cable is connected properly. If it is not, correctly connect the cable.
• For more details on the internal hard disk unit, refer to "7.7 Installing an Internal Hard Disk Unit"
• Are the jumper pins set correctly? If they are not, correctly set the jumper pins.
• Are the SCSI-ID and terminator correctly set? If they are not set, correctly set the SCSI-ID and