Chapter 9 Operation and Maintenance
■
Failed in Remote Installation
If remote installation fails, check the following.
●
Checking Services
Check that the DHCP, PXE Service, and TFTP Service are running.
For checking procedures, refer to "3.4 Remote Installation" (
●
Setting TFTP
To access TFTP Service, add a Guest account to the TFTP folder and set appropriate access rights.
For setting procedures, refer to "3.4 Remote Installation" (
●
Checking Network Startup Settings
The server must support network startup (PXE).
For setting procedures, refer to "
Performing Remote Installation" (
●
Checking the MAC Address
Check that the current MAC address is the correct MAC address of the server.
For the MAC address checking procedure, refer to "
Performing Remote Installation" (
●
Checking LAN Cable Connection
Check that the LAN cable is correctly connected to the Switch Blade connected to the specified MAC
address and that it is connected to the network.
■
An error occurs during backup on Windows Server 2003
In Windows Server 2003, the following error message may appear when specifying the backup file
storage destination in the backup device (DAT72 drive, etc.) connected to the SCSI card installed in this
server and backing up data using the OS standard backup software.
If the message is displayed, get the Service Pack 1 or Hotfix (817688) from web site of Microsoft, and
apply one of them.
The device reported an error on a request to write data to media.
Error reported: Invalid command. There may be a hard-ware or media
problem.
Please check the system event log for relevant fail-ures.