![PRIMERGY BX620 S2 User Manual Download Page 210](http://html.mh-extra.com/html/primergy/bx620-s2/bx620-s2_user-manual_1601715210.webp)
210
Chapter 8 Hardware Configuration/Utilities
8.2.11 Power Menu
Configures power supply settings.
table: Items on the Power Menu
Item
Setting
Description
APM 1.2 Interface
Disabled (Fixed parameter)
Sets whether or not to use APM 1.2 (power saving
function depending on BIOS).
After Power Failure
• Stay Off
• Last State (at the time of
purchase)
• Power On
Sets server operations to restart power supply when
the power is recovered from a power failure or the
main power of the chassis is turned on.
• Stay Off
Leaves the power turned off.
• Last State
Returns to the power state before a power failure
occurred.
• Power On
Turns the server on.
Note:
When operating UPS schedule under an OS
(Windows Server 2003 or Linux), which is
turned off after shutdown, set this item to
[Power On].
If this item is not set to [Power On], the
server will not automatically start at the
specified time.
F1
Esc
Select Item
Select Screen
Change Field
+-
General Help
Exit
F9
F10
Load defaults
Save and Exit
BIOS Setup Utility
Main
Advanced
Security
Exit
Power
Boot
APM 1.2 Interface [Disabled]
After Power Failure [Last State]
Tab
Select Field
v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc.
Summary of Contents for BX620 S2
Page 28: ...28 Chapter 1 Overview ...
Page 44: ...44 Chapter 2 Checking before OS Installation ...
Page 162: ...162 Chapter 5 Operations after OS Installation ...
Page 288: ...288 ...