SECTION 18: BODY
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
57
Section B Sika 205
1.
Apply
2.
Allow drying
Mandatory
Minimum
time
-
For a smooth surface
(aluminum, stainless,
steel, fiber glass (gelcoat side), etc.)
:
2 minutes
- Pour a porous surface (fiber glass (non
gelcoat side), etc.)
10 minutes
After 2 hours : Reactivate surface with Sika 205
Before applying any
other product
If surface seems dusty, greasy or with finger marks, start
operation again.
SECTION 3 SIDE PANEL INSTALLATION
3.00
A) Using a pencil, mark the double-face self adhesive
tape position onto vehicle side.
B)
Apply 1/8 X ½”double-face tape as per marking.
C) Compress
tape
D)
Remove protective film from double-face self adhesive
tape center section.
CHIX cloth