SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
17
MID 188 PSID # 137 FR Clearance lights (A44 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A44 J1:8 but
output not active
Front Clearance
Lights always ON
•
A44 module failure
•
Connector C45 corroded
•
Circuit 63A shorted to battery
FMI 4
Shorted Low
Output A44 J1:8
shorted to ground
Front Clearance
Lights not
working
•
A44 module failure
•
Connector C45 corroded
•
Circuit 63A shorted to ground
FMI 5
Open Circuit
A44 module does
not detect Front
Clearance Lights
Front Clearance
Lights not
working
•
A44 module failure
•
L16 open circuit
•
Circuit 63A open
FMI 6
Current
above normal
Output A44 J1:8
internal software
fuse active for
overcurrent
Front Clearance
Lights not
working
•
A44 module failure
•
Connector C45 corroded
•
Circuit 63A shorted to ground
MID 188 PSID # 128 Fr Flsh-Mkr LH (A45 J1:3)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:3 but
output not active
Front LH
flasher and
marker lights
always ON
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 21A shorted to battery
FMI 4
Shorted Low
Output A45 J1:3
shorted to ground
Front LH
flasher and
marker lights
not working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 21A shorted to ground
FMI 6
Current
above normal
Output A45 J1:3
internal software fuse
active for overcurrent
Front LH
flasher and
marker lights
not working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 21A shorted to ground
MID 188 PSID # 10 Fr Side Flsh (A48 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A48 J1:20 but
output not active
Flasher RH
Front side L64
always ON
•
A48 module failure
•
Flasher RH Front Side L64
failure
•
Circuit 23AA shorted to battery
FMI 4
Shorted Low
Output A48 J1:20
shorted to ground
Flasher RH
Front side L64
not working
•
A48 module failure
•
Flasher RH Front Side L64
failure
•
Circuit 23AA shorted to ground
FMI 6
Current
above normal
Output A48 J1:20
internal software fuse
active for overcurrent
Flasher RH
Front side L64
not working
•
A48 module failure
•
Circuit 23AA shorted to ground
MID 188 PSID # 58 Fr Start Sw (A36 JB:22)