SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
11
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A49 J1:13 but
output not active
Emergency
lights always
ON
•
A49 module failure
•
Relay R15 failure
•
Connector C35 corroded
•
Circuit 64 shorted to battery
FMI 4
Shorted Low
Output A49 J1:13
shorted to ground
Emergency
lights not
working
•
A49 module failure
•
Relay R15 failure
•
Connector C35 corroded
•
Circuit 64 shorted to ground
FMI 5
Open Circuit
A49 module does not
detect relay R15
Emergency
lights not
working
•
A49 module failure
•
Relay R15 open circuit
•
Circuit 64 open
FMI 6
Current
above normal
Output A49 J1:13
internal software fuse
active for overcurrent
Emergency
lights not
working
•
A49 module failure
•
Connector C35 corroded
•
Circuit 64 shorted to ground
•
Relay R15 low resistance
value (expected value ± 200
ohms)
MID 188 PSID # 44 Emergency Relay (A36 JA:24)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A36 JA:24 but
output not active
Engine will shut
down or cannot
be started
•
A36 module failure
•
Relay R21 failure
•
Connector C2 corroded
•
Connector C21 corroded
•
Circuit 911 shorted to battery
FMI 4
Shorted Low
Output A36 JA:24
shorted to ground
Emergency
cutout system
not working
•
A36 module failure
•
Relay R21 failure
•
Connector C2 corroded
•
Connector C21 corroded
•
Circuit 911 shorted to ground
FMI 5
Open Circuit
A36 module does not
detect Emergency
Cutout Relay R21
Emergency
cutout system
not working
•
A36 module failure
•
Relay R21 open circuit
•
Circuit 911 open
FMI 6
Current
above normal
Output A36 JA:24
internal software fuse
active for overcurrent
Emergency
cutout system
not working
•
A36 module failure
•
Connector C2 corroded
•
Connector C21 corroded
•
Circuit 911 shorted to ground
•
Relay R21 low resistance
value
MID 188 PSID # 101 Emgy & Aisle Lts (A46 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A46 J1:4 but
output not active
Aisle lights
always ON
•
A46 module failure
•
Connector C144 corroded
•
Circuit 5 shorted to battery
FMI 4
Shorted Low
Output A46 J1:4
shorted to ground
Aisle lights not
working
•
A46 module failure
•
Connector C144 corroded
•
Circuit 5 shorted to ground