MI14-40B / Page 4 / 10
<QF7720955 rev 2>
2. Remove the alternator belt (figure 2).
3. Unscrew the alternator pulley mounting nut
(figure 2).
4. Remove the alternator pulley (2 pulleys) (figure
2).
FIGURE 2
5. Remove the existing alternators. To do so,
unscrew identified mounting bolts on figure 3
and retain for use if in good condition.
6. Identify alternator cables and then disconnect
cables. Properly clean alternator stud terminals
and cable ring terminals as applicable using a
brass wire cup brush, a Scotch-Brite pad or an
emery cloth.
BRASS WIRE CUP BRUSH
FIGURE 3