SECTION 06B: ELECTRICAL
2
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
MID 188 PSID # 13 A/C Pres LoSd (A52 J1:14)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A52 J1:14
Low side
pressure not
displayed on
dash
•
A52 module failure
•
Se24 failure
•
Connector C91 corroded
•
Circuit 93-20 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A52 J1:14
Low side
pressure not
displayed on
dash
•
A52 module failure
•
Se24 failure
•
Connector C91 corroded
•
Circuit 93-20 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Se24
Low side
pressure not
displayed on
dash
•
A52 module failure
•
Se24 failure
•
Circuit 93-20 open
MID 188 SID # 69 Aux Bypass Sw (A42 J1:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A42 J1:10
Aux bypass
switch not
working
•
A42 module failure
•
Sw142 failure
•
Connector C71 corroded
•
Connector C171 corroded
•
Circuit AuxBP shorted to
battery
FMI 4
Shorted Low
Voltage below normal
on A42 J1:10
Aux bypass
switch always
ON
•
A52 module failure
•
Sw142 failure
•
Connector C71 corroded
•
Connector C171 corroded
•
Circuit AuxBP shorted to
ground
MID 188 SID # 61 (A45 J1:12)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A45 J1:12
Left side high
and low beam
not working
•
A45 module failure
•
Sw2 failure
•
Connector C71 corroded
•
Circuit 61-20 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A45 J1:12
Left high beam
always ON
•
A45 module failure
•
Sw2 failure
•
Connector C71 corroded
•
Circuit 61-20 shorted to ground