SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
35
MID 188 PSID # 165 Tag axle Sw (A43 J1:19)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A43 JB:19 but
output not active
Pressure Tag
Switch Sw64
not working
•
A43 module failure
•
Connector C71 or C171 corroded
•
Circuit 160 shorted to battery
FMI 4
Shorted Low
Input A43 J1:19
shorted to ground
Pressure Tag
Switch Sw64
always ON
•
A43 module failure
•
Pressure Tag Switch Sw64 failure
•
Connector C71 or C171 corroded
•
Circuit 160 shorted to ground
MID 188 PSID # 152 Tail Lights (A51 J1:8)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A51 J1:8 but
output not active
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 always ON
•
A51 module failure
•
Connector C119, C91 or
C120 corroded
•
Circuit 46 shorted to battery
FMI 4
Shorted Low
Output A51 J1:8
shorted to ground
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
•
A51 module failure
•
Connector C119, C91 or
C120 corroded
•
Circuit 46 shorted to ground
FMI 5
Open Circuit
A51 module does not
detect Tail Lights
L72, L74, L77, L78,
L79, L80, L82 or L83
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
•
A51 module failure
•
Circuit 46 open
FMI 6
Current
above normal
Output A51 J1:8
internal software fuse
active for overcurrent
Tail Lights L72,
L74, L77, L78,
L79, L80, L82 or
L83 not working
•
A51 module failure
•
Connector C119, C91 or
C120 corroded
•
Circuit 46 shorted to ground
MID 188 SID # 25 Trans Inh Sig (A50 J1:2)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A50 J1:2 but
output not active
Transmission
Shifting not
working
•
Transmission ECU failure
•
A50 module failure
•
Connector C717 corroded
•
Circuit 185 shorted to battery
FMI 4
Shorted Low
Output A50 J1:2
shorted to ground
Transmission
Shifting not
working
•
A50 module failure
•
Connector C717 corroded
•
Circuit 185 shorted to ground
FMI 5
Open Circuit
A50 module does not
detect Transmission
ECU
Transmission
Shifting not
working
•
A50 module failure
•
Circuit 185 open
•
Transmission ECU failure
FMI 6
Current
above normal
Output A50 J1:2
internal software fuse
active for overcurrent
Transmission
Shifting not
working
•
A50 module failure
•
Connector C717 corroded
•
Circuit 185 shorted to ground
MID 188 PSID # 168 Trans Neutral Sens (A50 J1:11)