SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
23
•
Circuit 126F shorted to ground
FMI 5
Open Circuit
A41 module does not
detect Knee. Down
Solenoid Valve So16
Kneeling down
not working
•
A41 module failure
•
Kneeling down solenoid valve
So16 open circuit
•
Circuit 126F open
FMI 6
Current
above normal
Output A41 J1:14
internal software fuse
active for overcurrent
Kneeling down
not working
•
A41 module failure
•
Connector C4 corroded
•
Connector C172 corroded
•
Circuit 12W shorted to ground
MID 188 PSID # 93 Knee Down Sw (A41 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A41 J1:7 but
switch Sw10A not
active
Kneeling down
not working
•
A41 module failure
•
Kneeling switch Sw10A failure
•
Connector C71 corroded
•
Connector C170 corroded
•
Circuit 126A shorted to battery
FMI 4
Shorted Low
Input A41 J1:7
shorted to ground
Kneeling down
always ON,
coach cannot
be raised
•
A41 module failure
•
Kneeling switch Sw10A failure
•
Connector C71 corroded
•
Connector C170 corroded
•
Circuit 126A shorted to ground
MID 188 PSID # 94 Knee Up Sw (A41 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A41 J1:6 but
switch Sw10A not
active
Kneeling up not
working
•
A41 module failure
•
Kneeling switch Sw10A failure
•
Connector C71 corroded
•
Connector C170 corroded
•
Circuit 126B shorted to battery
FMI 4
Shorted Low
Input A41 J1:6
shorted to ground
Kneeling Up
always ON,
coach cannot
be lowered
•
A41 module failure
•
Kneeling switch Sw10A failure
•
Connector C71 corroded
•
Connector C170 corroded
•
Circuit 126B shorted to ground
MID 188 SID # 81 Kneeling Level Se (A46 J1:13)
Type of
fault:
FMI
Description:
Fault
Condition:
Possible Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage
present on
signal A46
J1:13 but
sensor Se79
not active
Momentary switch
function lost, holding
switch will raise coach
past the normal ride
height
•
A46 module failure
•
Kneeling level sensor Se79
failure
•
Connector CSe79 corroded
•
Circuit ANA-KneeLevel shorted
to battery
FMI 4
Shorted Low
Signal A46
J1:13 shorted
to ground
Momentary switch
function lost, holding
switch will lower coach
•
A46 module failure
•
Kneeling level sensor Se79
failure