SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
1
MULTIPLEX ERROR MESSAGES TROUBLE SHOOTING LIST
MID (Message Identification Description)
: Identification of a control unit
PID (Parameter Identification Description)
: Identification of a parameter (value)
PPID (Proprietary Parameter Identification
: Unique Identification of a parameter (value)
Description)
SID (Subsystem Identification Description) : Identification of a component
PSID (Proprietary Subsystem Identification : Unique Identification of a component
Description)
FMI (Failure Mode Identifier) : Identification of fault types
MID 188 PSID # 4 A/C Clutch So9 (A52 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A52 J1:20 but
output not active
A/C clutch
always ON
•
A52 module failure
•
Connector C91 corroded
•
Circuit 77BA shorted to battery
FMI 4
Shorted Low
Output A52 J1:20
shorted to ground
A/C clutch not
working
•
A52 module failure
•
Connector C91 corroded
•
Circuit 77BA shorted to ground
FMI 5
Open Circuit
A52 module does not
detect A/C clutch So9
A/C clutch not
working
•
A52 module failure
•
So9 open circuit
•
Se29 failure
•
Circuit 77BA open
•
Circuit 78 open
•
Circuit ORA2 open
FMI 6
Current
above normal
Output A52 J1:20
internal software fuse
active for overcurrent
A/C clutch not
working
•
A52 module failure
•
Connector C91 corroded
•
Circuit 77BA shorted to ground
•
A/C clutch resistance value
lower than 5 ohms (7 ohms
expected)
MID 188 PSID # 12 A/C Pres HiSd (A52 J1:13)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A52 J1:13
High side
pressure not
displayed on
dash
•
A52 module failure
•
Se23 failure
•
Connector C91 corroded
•
Circuit 77-20 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A52 J1:13
High side
pressure not
displayed on
dash
•
A52 module failure
•
Se23 failure
•
Connector C91 corroded
•
Circuit 77-20 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Se23
High side
pressure not
displayed on
dash
•
A52 module failure
•
Se23 failure
•
Circuit 77-20 open