SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
39
fuse active for
overcurrent
working
corroded
•
Circuit 304 shorted to ground
MID 188 SID # 24 WCLDorSig to USonic (A53 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A53
J1:7 but output
not active
WCL Door
open Relay
R47 always ON
•
A53 module failure
•
WCL Door open Relay R47 failure
•
Connector C27, C31 or C29
corroded
•
Circuit 306 shorted to battery
FMI 4
Shorted Low
Output A53 J1:7
shorted to ground
WCL Door
open Relay
R47 not
working
•
A53 module failure
•
WCL Door open Relay R47 failure
•
Connector C27, C31 or C29
corroded
•
Circuit 306 shorted to ground
FMI 5
Open Circuit
A53 module does
not detect WCL
Door open Relay
R47
WCL Door
open Relay
R47 not
working
•
A53 module failure
•
WCL Door open Relay R47 failure
•
Circuit 306 open
FMI 6
Current
above normal
Output A53 J1:7
internal software
fuse active for
overcurrent
WCL Door
open Relay
R47 not
working
•
A53 module failure
•
Connector C27, C31 or C29
corroded
•
Circuit 306 shorted to ground