SECTION 06B: ELECTRICAL
28
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
•
Connector C15, C21, C35,
C57 or C75 corroded
•
Circuit 43 shorted to ground
FMI 5
Open Circuit
A54 module does not
detect P Rack RH
Fan Mo11
P Rack RH Fan
Mo11 not working
•
A54 module failure
•
P Rack RH Fan Mo11 open
circuit
•
Circuit 43 open
FMI 6
Current
above normal
Output A54 J1:2
internal software fuse
active for overcurrent
P Rack RH Fan
Mo11 not working
•
A54 module failure
•
Connector C15, C21, C35,
C57 or C75 corroded
•
Circuit 43 shorted to ground
MID 188 PSID # 21 P Rack Fan (A41 J1:20)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A41 J1:20 but
Switch Sw27 not
active
Parcel Rack
Fans not
working
•
A41 module failure
•
Parcel Rack Fan switch Sw27
failure
•
Connector C74 corroded
•
Circuit 43G shorted to battery
FMI 4
Shorted Low
Output A41 J1:20
shorted to ground
Parcel Rack
Fans always
ON
•
A41 module failure
•
Parcel Rack Fan switch Sw27
failure
•
Connector C74 corroded
•
Circuit 43G shorted to ground
MID 188 PSID # 162 Park brak Sens (A36 JB:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A36 JB:9
Parking Brake
sensor not
working
•
Vehicle ECU failure
•
A36 module failure
•
Connector C4 or C48 corroded
•
Circuit 91 shorted to battery
FMI 4
Shorted Low
Input A36 JB:9
shorted to ground
Parking Brake
sensor always
ON
•
Vehicle ECU failure
•
A36 module failure
•
Parking Brake sensor Se18
failure
•
Connector C4 or C48 corroded
•
Circuit 91 shorted to ground
MID 188 PSID # 163 Park brake Sol (A42 J1:12)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A42 J1:12 but
output not active
Parking Brake
solenoid valve
So17 not
working
•
A42 module failure
•
Parking Brake solenoid valve
So17 failure
•
Connector C4 or C172 corroded
•
Circuit 8 shorted to battery
FMI 6
Current
above normal
Output A42 J1:12
internal software fuse
active for overcurrent
Parking Brake
solenoid valve
So17 not
working
•
A42 module failure
•
Connector C4 or C172 corroded
•
Circuit 8 shorted to ground