SECTION 18: BODY
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
49
15.5.4 CONDENSER COMPARTMENT DOOR
FIGURE 45: CONDENSER DOOR
1. Open the condenser door.
2. Loosen the screws fixing the hinge to hinge
attachment or hinge to door assembly.
Loosening the screws allows the condenser
door assembly to be shifted "LEFT or
RIGHT" and "UP or DOWN" or “IN and
OUT”.
3. Adjust condenser door assembly position at
the hinge.
4. Respect the required gap between exterior
finishing panels.
5. Tighten the screws.
6. Check that the door swings freely and
closes properly. It may be necessary to
adjust the door latch to get proper fit and
operation.
15.5.5 FUEL FILLER DOOR
1. Open the fuel filler door.
2. Loosen the screws holding the panel to
hinge assembly.
3. Adjust the fuel filler door position according
to distance required between exterior
finishing panels.
4. Tighten the nuts.
5. Check that the door swings freely and
closes properly.
FIGURE 46: FUEL FILLER DOOR
03046
15.5.6 BAGGAGE COMPARTMENT FLOOR
Repair of Mantex Urethane Covering
Minor Repair
Use “Dupont IMRON” paint. Apply using a paint
brush or roller depending on gravity.