SECTION 06B: ELECTRICAL
10
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
FMI 3
Shorted High
Voltage present on
output A44 J1:2 but
output not active
Dash damper
not moving
•
A44 module failure
•
Dash Damper Mo3 failure
•
Connector C72 corroded
•
Circuit 68A shorted to battery
FMI 4
Shorted Low
Output A44 J1:2
shorted to ground
Dash damper
not moving
•
A44 module failure
•
Dash Damper Mo3 failure
•
Connector C72 corroded
•
Circuit 68A shorted to ground
FMI 6
Current
above normal
Output A44 J1:2
internal software fuse
active for overcurrent
Dash damper
not moving
•
A44 module failure
•
Connector C72 corroded
•
Circuit 68A shorted to ground
•
Mo3 low resistance value
MID 188 PSID # 30 Drv Rec Cylind (A47 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A47 J1:4 but
output not active
Driver’s area
always in
recirculation
mode.
Windshield could
fog up
•
A47 module failure
•
Gaz Cylinder driver LH L283
failure
•
Gaz Cylinder driver RH L203
failure
•
Circuit 65D shorted to battery
FMI 4
Shorted Low
Output A47 J1:4
shorted to ground
Recirculation
mode not
working, low A/C
performance
•
A47 module failure
•
Gaz Cylinder driver LH L283
failure
•
Gaz Cylinder driver RH L203
failure
•
Circuit 65D shorted to ground
FMI 5
Open Circuit
A47 module does
not detect Gaz
Cylinder driver LH
L283 and RH L203
Recirculation
mode not
working. Low A/C
performance
•
A47 module failure
•
Gaz Cylinder driver LH L283
open circuit
•
Gaz Cylinder driver RH L203
open circuit
•
Circuit 65D open
•
Circuit ORC3 open
FMI 6
Current
above normal
Output A47 J1:4
internal software
fuse active for
overcurrent
Recirculation
mode not
working. Low A/C
performance
•
A47 module failure
•
Circuit 65D shorted to ground
•
LH L283 or RH L203 low
resistance value
MID 188 PSID # 82 Elec Horn SW61 (A45 J1:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage above
normal on A45 J1:10
Electrical horn
not working
•
A45 module failure
•
Connector C71 corroded
•
Circuit 69 shorted to battery
FMI 4
Shorted Low
Voltage below normal
on A45 J1:10
Electrical horn
always ON
•
A45 module failure
•
Connector C71 corroded
•
Circuit 69 shorted to ground
MID 188 SID # 47 Emergency Lt R15 (A49 J1:13)