SECTION 06B: ELECTRICAL
24
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
below standard
kneeling height and
raise coach above the
normal ride height
•
Connector CSe79 corroded
•
Circuit ANA-KneeLevel shorted
to ground
MID 188 PSID # 98 Lavatory Fan4 (A52 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A52 J1:4
shorted to ground
Air Exhaust
Fan Mo14 not
working
•
A52 module failure
•
Air Exhaust Fan Mo14 failure
•
Connector C91 corroded
•
Circuit 225 shorted to ground
FMI 5
Open Circuit
A52 module does not
detect Air Exhaust
Fan Mo14
Air Exhaust
Fan Mo14 not
working
•
A52 module failure
•
Air Exhaust Fan Mo14 open
circuit
•
Circuit 225 open
FMI 6
Current
above normal
Output A52 J1:4
internal software fuse
active for overcurrent
Air Exhaust
Fan Mo14 not
working
•
A52 module failure
•
Connector C91 corroded
•
Circuit 225 shorted to ground
MID 188 PSID # 142 Low Beam LH (A45 J1:7)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A45 J1:7 but
output not active
LH Low beam
Headlamp
L60A always
ON
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 58L shorted to battery
FMI 4
Shorted Low
Output A45 J1:7
shorted to ground
LH Low beam
Headlamp
L60A not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 58L shorted to ground
FMI 6
Current
above normal
Output A45 J1:7
internal software fuse
active for overcurrent
LH Low beam
Headlamp
L60A not
working
•
A45 module failure
•
Connector C4 corroded
•
Connector C242 corroded
•
Circuit 58L shorted to ground
MID 188 PSID # 146 Low Beam RH (A48 J1:4)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A48 J1:4 but
output not active
RH Low beam
Headlamp
L59A always
ON
•
A48 module failure
•
Connector C243 corroded
•
Circuit 58R shorted to battery
FMI 4
Shorted Low
Output A48 J1:4
shorted to ground
RH Low beam
Headlamp
L59A not
working
•
A48 module failure
•
Connector C243 corroded
•
Circuit 58R shorted to ground
FMI 6
Current
above normal
Output A48 J1:4
internal software fuse
active for overcurrent
RH Low beam
Headlamp
L59A not
•
A48 module failure
•
Connector C243 corroded