SECTION 06B: ELECTRICAL
26
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
MID 188 SID # 80 Next Stop Sign (A41 J1:13)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A41 J1:13 but
output not active
Next Stop Light
L310 always
ON
•
A41 module failure
•
Connector C70 corroded
•
Circuit 10 shorted to battery
FMI 4
Shorted Low
Output A41 J1:13
shorted to ground
Next Stop Light
L310 not
working
•
A41 module failure
•
Connector C70 corroded
•
Circuit 10 shorted to ground
FMI 6
Current
above normal
Output A41 J1:13
internal software fuse
active for overcurrent
Next Stop Light
L310 not
working
•
A41 module failure
•
Connector C70 corroded
•
Circuit 10 shorted to ground
MID 188 SID # 70 Next Stop Sw (A42 J1:9)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A42 J1:9 but
switch Sw5 not active
Next Stop
Request not
working
•
A42 module failure
•
Connector C70 corroded
•
Connector C25A corroded
•
Circuit 4C shorted to battery
FMI 4
Shorted Low
Input A42 J1:9
shorted to ground
Next Stop
Request
always ON
•
A42 module failure
•
Connector C70 corroded
•
Connector C25A corroded
•
Circuit 4C shorted to ground
MID 188 SID # 75 Oil Separator (A52 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A52 J1:6 but
output not active
Drain valve
discharge
always ON
•
A52 module failure
•
Oil separator L350A failure
•
Connector C27 corroded
•
Circuit OilSep shorted to
battery
FMI 4
Shorted Low
Output A52 J1:6
shorted to ground
Drain valve
discharge not
working
•
A52 module failure
•
Oil Separator L350A failure
•
Connector C27 corroded
•
Circuit OilSep shorted to
ground
FMI 5
Open Circuit
A52 module does not
detect oil Separator
L350A
Drain valve
discharge not
working
•
A52 module failure
•
Oil separator L350A open
circuit