SECTION 06B: ELECTRICAL
38
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
MID 188 PSID # 43 Upper Brk Lamp (A51 J1:6)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A51
J1:6 but output
not active
Upper Stop Lights
RH L78 or LH L80
always ON
•
A51 module failure
•
Connector C91, C119 or C120
corroded
•
Circuit 82Up shorted to battery
FMI 4
Shorted Low
Output A51 J1:6
shorted to ground
Upper Stop Lights
RH L78 or LH L80
not working
•
A51 module failure
•
Connector C91, C119 or C120
corroded
•
Circuit 82Up shorted to ground
FMI 6
Current
above normal
Output A51 J1:6
internal software
fuse active for
overcurrent
Upper Stop Lights
RH L78 or LH L80
not working
•
A51 module failure
•
Connector C91, C119 or C120
corroded
•
Circuit 82Up shorted to ground
MID 188 SID # 30 WakeUp Rly (A36 JA:15)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 4
Shorted Low
Output A36 JA:15
shorted to ground
Various systems
not working
depending on relay
or position
•
A36 module failure
•
Various WUp Relays failure
•
Connector C2 or C21 corroded
•
Circuit 85B shorted to ground
FMI 5
Open Circuit
A36 module does
not detect 24v Fr
WUp relay R18,
12v Fr WUp relay
R19, 12v Rr WUp
relay R17 or 12v
Rr Engine ECU
relay R34
Various systems
not working
depending on relay
or position
•
A36 module failure
•
Various WUp Relays R17,
R18, R19, R34 open circuit
•
Circuit 85B open
FMI 6
Current
above normal
Output A36 JA:15
internal software
fuse active for
overcurrent
Various systems
not working
depending on relay
or position
•
A36 module failure
•
Connector C2 or C21 corroded
•
Circuit 85B shorted to ground
MID 188 PSID # 176 WCL Pump Rly (A53 J1:5)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A53
J1:5 but output
not active
WCL Pump
Assy L207 can
be operated is
sensor Se100
is active
•
A53 module failure
•
WCL Door open Relay R47 failure
•
Connector C27, C31 or C29
corroded
•
Circuit 304 shorted to battery
FMI 4
Shorted Low
Output A53 J1:5
shorted to ground
WCL Pump
Assy L207 not
working
•
A53 module failure
•
WCL Door open Relay R47 failure
•
Connector C27, C31 or C29
corroded
•
Circuit 304 shorted to ground
FMI 6
Current
above normal
Output A53 J1:5
internal software
WCL Pump
Assy L207 not
•
A53 module failure
•
Connector C27, C31 or C29