SECTION 06B: ELECTRICAL
DOB 2490-2789 | X3-45 Commuter PA1605 Maintenance Manual (Final Version – Rev.2 April 2016)
31
FMI 3
Shorted High
Voltage present on
input A42 J1:19 but
switch Sw5 not active
Reading
Lights not
working
•
A42 module failure
•
Reading Lamp Test switch Sw5
failure
•
Connector C72 corroded
FMI 4
Shorted Low
Input A42 J1:19
shorted to ground
Reading
Lights always
ON
•
A42 module failure
•
Reading Lamp Test switch Sw5
failure
•
Connector C72 corroded
•
Wire between A42 J1:19 and
Sw5 pin 3 shorted to ground
MID 188 PSID # 113 Read Lts Rly (A49 J1:15)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
output A49 J1:15 but
output not active
Reading
Lights always
ON
•
A49 module failure
•
Reading Lights Master Relay
R14 failure
•
Circuit 74C shorted to battery
FMI 4
Shorted Low
Output A49 J1:15
shorted to ground
Reading
Lights not
working
•
A49 module failure
•
Reading Lights Master Relay
R14 failure
•
Circuit 74C shorted to ground
FMI 5
Open Circuit
A49 module does not
detect Reading Lights
Master Relay R14
Reading
Lights not
working
•
A49 module failure
•
Reading Lights Master Relay
R14 open circuit
•
Circuit 74C open
FMI 6
Current
above normal
Output A49 J1:15
internal software fuse
active for overcurrent
Reading
Lights not
working
•
A49 module failure
•
Circuit 74C shorted to ground
•
Relay R14 coil shorted to ground
MID 188 PSID # 114 Read Lts Sw (A41 J1:10)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present on
input A41 J1:10 but
switch Sw26 not
active
Reading
Lights not
working
•
A41 module failure
•
Reading Lamp Switch Sw26 failure
•
Connector C71 corroded
•
Circuit 74 shorted to battery
FMI 4
Shorted Low
Input A41 J1:10
shorted to ground
Reading
Lights
always ON
•
A41 module failure
•
Reading Lamp Switch Sw26 failure
•
Connector C71 corroded
•
Circuit 74 shorted to ground
MID 188 PSID # 131 RearFlsh LH (A51 J1:21)
Type of
fault:
FMI
Description:
Fault Condition:
Possible
Symptoms:
Possible Causes:
FMI 3
Shorted High
Voltage present
on output A51
J1:21 but output
not active
Rear Flasher Light
LH L71, upper rear
LH L286 and Rear
Side markers LH
L75 always ON
•
A51 module failure
•
Connector C91 or C120
corroded
•
Circuit 21AA shorted to battery