NOTE
The spray must be switched off when using an instrument without a
waterline inside the handpiece.
NOTE
The instrument spray operated with the foot control can be disabled in the
service mode, in which case you can switch the spray on and off only from
the control panel. Contact your Planmeca dealer.
23.7.4 Speed/power limit
When the turbine’s speed/power limit is on and the preset value is, for
example, 50%, the foot control pedal movement controls the speed/power
between 5 - 50% instead of the normal range of 5 - 100%. The preset
maximum value is displayed on the control panel when the turbine is picked
up from the instrument console.
When the speed/power limit is on, the indicator light on the control panel
button is green.
Control panel: Press Turbine speed/power limit to reduce the turbine’s speed
or power to a preset level. Press Turbine speed/power limit again to switch
the speed/power limit off.
NOTE
The foot control can be configured so that the turbine's speed or power is
limited to a preset level when you push the left-side knob down. Contact
your Planmeca dealer.
NOTE
Check the indicator light on the control panel to verify that pushing the left-
side knob down activates the correct function.
NOTE
The speed/power limit can be programmed. See section "Instrument speed/
NOTE
The turbine speed/power limit does not affect the air driven instruments for
which quickstart has been selected.
NOTE
Note that the speed/power limit depends on the instrument.
23.7.5 Momentary spray
When you are driving the instrument, you can activate the momentary spray
by pressing the foot control pedal down. The spray will continue until you
remove your foot from the pedal.
NOTE
The momentary spray can be enabled and configured in the service mode,
contact your Planmeca dealer.