Section 6-1-5
(2) When the white level adjustment is terminated abnormally
Screen T45
Function No.
Display
Scanner status
Displays
“c”.
The adjustment has terminated abnormally.
Note: The major reason of abnormal termination is incorrect setting of the test sheet. Set the test sheet correctly and try the
magnification adjustment again.
<Available buttons at screen T45>
Function
button: Displays error information (screen T46)
Send to button: Terminates this mode and returns to screen T04.
Screen T46
Function No.
Display
Description
Countermeasure when abnormal termination
frequently occurs
1: media error
The tested sheet may not be the specified one. Check
the test sheet.
2: No paper
It seems Lamp or Optical Unit is faulty. Replace
defective parts.
<Available buttons at screen T46>
Send to button: Terminates this mode and return to screen T04.