![PFU Limited fi-6130 Maintenance Manual Download Page 60](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731060.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
60
/
257
Section 4-3-19
4-3-19 “E6: Operator panel alarm”
Table 4-3-19
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to turn it
OFF, and after more than 2 seconds elapse, press the power button to
turn the scanner ON.
2
Is the cable connected correctly?
Refer to Section 5-10-9 “Panel PCA.”
3
It seems the installed Panel PCA has
been used in other scanner before and it
may be faulty one. Replace it with the
new Panel PCA.
Replace the Panel PCA with new one after saving the EEPROM data.
Then conduct Maintenance mode #7 by referring to Section 6-1-8.
4-3-20 “E7: EEPROM alarm”
Table 4-3-20
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Is the cable connected correctly?
Refer to Section 5-10-9 “Panel PCA.”
3
Replace the Panel PCA and see if the
error is resolved.
Refer to Section 5-10-9 for replacement.
4
Replace the Control PCA and see if the
error is resolved.
Refer to Section 5-11 for replacement.
4-3-21 “E8: SCSI alarm”
Table 4-3-21
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Check if the SCSI cable or other SCSI
devices connected to the scanner cause
this error.
The scanner can work even after this error occurs.
Go to item 3 if you want to remove this error.
3
Replace the Control PCA and see if the
error is resolved.
Refer to Section 5-11 for replacement.
4-3-22 “E9: Image memory alarm”
Table 4-3-22
Item
No.
Check items
How/where to check
1
Does the same symptom occur after
turning OFF and ON the scanner?
Press power button of the scanner for more than 2 seconds to
turn it OFF, and after more than 2 seconds elapse, press the
power button to turn the scanner ON.
2
Replace the Control PCA and see if the
error is resolved.