![PFU Limited fi-6130 Maintenance Manual Download Page 131](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731131.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
131
/
257
Section 5-11
(3) Remove four screws (circles below) of the Control PCA, and then remove the bracket.
<Installation>
Follow the removing procedure in reverse.
Note: Tighten four screws of the Control PCA in the following order.
1. M3 screw D (1)
2. Inch screws F (2)
3. M3 screw C with washer (1)
Note: Before closing the PCB unit, draw the cables to the right, and check that the nylon band is located righter than the
connector edge (left edge).
1. M3 screw D
2. Inch screw F
3. M3 screw C with washer
Bracket
03
OK
The nylon band locates at right
side of the connector edge (left).
Connector edge
Nylon band
Nylon band
NG
The nylon band locates at left side
of the connector edge (left).
Nylon band
Connector edge
Nylon band