08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
160
/
257
Section 6-1-3
6-1-3 Maintenance mode #2: Main scanning / Sub-scanning magnification adjustment
In this mode, the magnification correction values for main/sub-scanning are automatically calculated to satisfy the following
adjustment value:
Adjustment value
Main scanning: Within ±1.0%
Sub scanning: Within ±1.0% (Without stop and start during scanning)
: Within ±2.0% (With stop and start during scanning)
Before this adjustment, please prepare the Test sheet described in Figure 6-1-3.
If Main-scanning magnification (ADF front or back, or FB) is adjusted, then run Offset adjustment (ADF front or back, or FB)
described in Section 6-1-4.
[How to start]
(1) From screen T04, Press the Function (
△
or
▽
) button to select (Maintenance mode #2) and press the Scan/Stop button.
A number is shown on the Function No. Display indicating the magnification to be adjusted as follows:
Function No. Display
Magnification to be adjusted
Remarks
0
ADF sub- scanning magnification adjustment
Default
1
ADF main scanning magnification adjustment (front)
2
ADF main scanning magnification adjustment (back)
3
FB sub-scanning magnification adjustment
FB models (fi-6240/fi-6230) only
4
FB main scanning magnification adjustment
FB models (fi-6240/fi-6230) only
(2) Select the magnification you want to change by pressing Function button.
(3) For the ADF adjustment, set the Test sheet on the ADF paper chute (Chute Unit), and adjust the side guide to the width of the
test sheet.
For the FB adjustment, set the Test sheet on the Document bed to be aligned with the reference point (left of the Document
bed, front edge), and remove the Document Cover. Avoid working near light source such as fluorescent lamp.
(4) Press Scan/Stop button to start the adjustment.
[How to end]
Press Send to button during operation. The operation stops and the Maintenance mode selection screen (T04) appears.