![PFU Limited fi-6130 Maintenance Manual Download Page 183](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731183.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
183
/
257
Section 7-2-1
Note: To avoid damaging the document sensors, tale care that the cloth does not get hooked into them when cleaning the
inside of the ADF.
- Brake roller
Lightly clean the Brake roller along the grooves on the roller
taking care not to scratch the roller surface. When cleaning the
Brake roller, remove it from the scanner. For how to remove
the Brake roller, refer to Section 7-3-3 “Replacing the Brake
rollers.”
- Pick roller
Lightly clean the Pick roller along the grooves on the roller taking care not to scratch the roller surface. Take particular
care in cleaning this roller as black debris on it adversely affects the pickup performance.
- Plastic roller
Lightly clean the Plastic roller taking care not to damage the roller surface. Take particular care in cleaning this roller
as black debris on it adversely affects the pickup performance. Be careful not to damage the sponges beside the rollers.
- Glass
Clean lightly.
If the glass is dirty, vertical black streaks may appear in the scanned images.
- Ultrasonic sensor
Clean lightly with a dry cloth.
If the glass is dirty, vertical black streaks may appear in the scanned images.
Document sensor