![PFU Limited fi-6130 Maintenance Manual Download Page 224](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731224.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
224
/
257
Section 8-6-8
<Removal-FPC CABLE>
(5) Remove two plastic parts from the Holder with a flat-blade screwdriver.
Be careful not to lose the rubber cushions at the bottom of the Holder.
(6) Remove one end of the FPC CABLE from the HOLDER.
(7) Withdraw the FPC CABLE from all the cable holding ribs.
<Installation-FPC CABLE>
Follow the removing procedure in reverse by taking care of the following point.
1. Fold the new FPC Cable as shown in the right figure.
2. Small plastic parts come with the FPC Cable. Insert two small
plastic parts into the holes of the FPC Cable near electrodes.
3. Route the new FPC Cable as shown in the following figure.
HOLDER ASSY3
Two plastic parts
Rubber cushions
Remove FPC Cable
from Holder
Holder
FPC Cable
Holding ribs
46
±
1 mm
Contacts of FPC Cable
shall be opposite side.
Small Plastic parts
Electrodes on FPC Cable