![PFU Limited fi-6130 Maintenance Manual Download Page 27](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731027.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
27
/
257
Section 2-2-1
2-2 Installing the scanner
2-2-1 For safety installation
Before installing the scanner, read the following cautions carefully to avoid scanner trouble.
Refer to Section 1-1-3 “Environmental Specifications” for information of power source and scanner dimensions.
■
Install the scanner away from strong magnetic fields and other sources of noise.
■
Do not install the scanner near heating apparatus or in the direct sunlight.
■
Install the scanner in a location which is level and subject to minimal vibration.
■
Do not install the scanner in locations subject to humidity and dust.
■
Do not block the ventilation ports.
■
Protect the scanner from static electricity.
■
Use proper AC voltage.
■
Make sure the rubber pads on the bottom of the scanner grounds evenly.
2-2-2 Installation
(1) fi-6140/fi-6130 If you wish to install the imprinter (optional), refer to Section 8-3-2 before performing the following
procedures.
(2) fi-6240/fi-6230 Unlock the Transport lock.
The carrier unit inside the fi-6240/fi-6230 is fixed in place with the
transport lock to prevent the scanner from being damaged during
transportation. To unlock the transport lock, slide the transport lock
switch on the scanner front.
(3) Referring to Section 5-8-1, attach the ADF paper chute (Chuter Unit).
(4) Connect the AC cable to the AC Adapter.
Note: Use only the supplied AC adapter.
(5) Connect the AC adapter connector to the scanner’s DC inlet. (right
figure)
(6) Plug the AC cable into an outlet. If you want to plug it into a two-slot
outlet, use the supplied adapter plug.
Notes:
- Before plugging the adapter plug into an outlet, be sure to establish a
ground.
- The Function Number Display and LED of the operator panel of the
scanner may flash for an instant when the AC cable is plugged into
an outlet. This is a phenomenon due to the initial diagnosis, but not a
failure.