08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
136
/
257
Section 5-12-2
<Installation>
Follow the removing procedure in reverse.
Note: Adjust the FB belt tension.
(1) Hook the FB Belt onto the FB Motor and the adjusting pulley, and then temporarily joint the adjusting plate.
Do NOT install the OPT Box Unit.
(2) - Place the belt tension adjusting spring that is attached to the Maintenance Part as shown below.
- Tighten the screw C (circle below).
- Remove the belt tension adjusting spring.
Adjusting spring
FB Belt
Adjusting plate
Adjusting pulley
FB Belt
FB Motor
Adjusting pulley
Adjusting plate