08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
193
/
257
Section 7-3-4
(5)
Attach a new Pick roller.
Insert the new Pick roller aligning the screw on the shaft with the slot in the Pick roller.
①
Pick roller shaft
②
Screw
③
Slot
④
Pick roller
Note: Make sure that the Pick roller is correctly attached. The incompletely-attached Pick roller might cause
document jams or other feed errors. When attaching the Pick roller to the shaft, make sure that the roller’s tab
clicks into place.
(6)
Attach the Pick roller to the scanner in the reverse order of removing.
1) Set the right side of the Pick roller into place first, then fix the left side to the roller.
2) Rotate the Pick roller lever in the direction of the arrow.
3) Close the Guide P ASSY (Sheet Guide).
(7)
Close the ADF. Press down on the center of the ADF to return it to
its original position until the ADF button locks.
(8)
Attach the ADF paper chute (Chuter Unit) to the scanner
(9)
Reset the Pick roller counter. (Refer to Section 7-3-2.)
Lever