![PFU Limited fi-6130 Maintenance Manual Download Page 144](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731144.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
144
/
257
Section 5-12-5
<Installation>
Follow the removing procedure in reverse.
Blow out the dust inside of the Glass and the OPT Unit with air before installation.
Install the OPT unit in the order of 1
Æ
2.
Note: Face the convex side down when installing the OPT Hold Plate.
Note: Perform the following adjustments after replacing the parts.
- Referring to Section 6-1-3 “Maintenance Mode #2,” adjust the magnification.
- Referring to Section 6-1-4 “Maintenance Mode #3,” adjust the offset.
- Referring to Section 6-1-5 “Maintenance Mode #4,” adjust the white level.
2
1