![PFU Limited fi-6130 Maintenance Manual Download Page 55](http://html1.mh-extra.com/html/pfu-limited/fi-6130/fi-6130_maintenance-manual_1535731055.webp)
08
July 27, 09 K.Okada
A.Miyoshi I.Fujioka
Refer to Revision Record on page 2.
TITLE
fi-6140/fi-6240/fi-6130/fi-6230/fi-614PR
Maintenance Manual
07
Nov.12, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
CUST.
06
Mar.10, 08 K.Okada
T.Anzai
I.Fujioka
Refer to Revision Record on page 2.
DRAW
No.
P1PA03540-B0XX/6
Rev. DATE DESIGN CHECK APPR. DESCRIPTION
Design
July 27, 2007
K.Okada
CHECK
K.Okada
APPR.
T.Anzai
PFU LIMITED
Page
55
/
257
Section 4-3-9
4-3-9 Scanned image is misaligned with ADF scanning
Table 4-3-9
Item
No.
Check items
How/where to check
1
Check the items listed in the right
column.
- Does the document satisfy the paper specifications described
in Section 1-1-6?
- Are the scan settings correct for the application software
used?
2
Clean feed rollers, Eject rollers and
plastic roller and see if the error is
resolved.
Refer to Section 7-2-1.
3
Adjust the offset by Maintenance mode.
Refer to Section 6-1-4.
4
Check the Pick roller and Brake roller
counter to see if they need to be
replaced.
Refer to Section 6-1-6 “Maintenance mode #5: Consumable
counter display and reset” and Section 7-3-1 “Consumables.”
5
Is the OPT Unit installed correctly?
6
Replace the OPT Unit and see if the
error is resolved.
ADF (front) scanning: Refer to Section 5-9-6.
ADF (back) scanning: Refer to Section 5-10-4.
7
When the backside image is misaligned,
replace Upper Unit and see whether the
error is resolved.
Refer to Section 5-10-1.
8
When the front side image is misaligned,
replace Base Unit and see whether the
error is resolved.
Refer to Section 5-9-1.
4-3-10 Scan magnification factor abnormal with ADF scanning
Table 4-3-10
Item
No.
Check items
How/where to check
1
Check the items listed in the right
column.
Are the scan settings correct for the application software used?
2
Adjust the magnification in Maintenance
mode.
Refer to Section 6-1-3.
When main scanning magnification is abnormal: Go to Item
No.3
When sub-scanning magnification is abnormal: Go to Item
No.8
3
Clean feed rollers roller and plastic roller
and see if the error is resolved.
Refer to Section 7-2-1.
4
Does any foreign object get inside Upper
Unit and disturb transporting operation
by feed rollers?
Open the ADF and check Upper Unit gear.
5
Check the Pick roller and Brake roller
counter to see if they need to be
replaced.
Refer to Section 6-1-6 “Maintenance mode #5: Consumable
counter display and reset” and Section 7-3-1 “Consumables.”
6
Is the ADF Motor belt loose?
Refer to Section 5-10-3.
7
Replace the ADF Motor and see whether
the error is resolved.
Refer to Section 5-10-3.
8
Is the OPT Unit installed correctly?
9
Replace the OPT Unit and see whether
the error is resolved.
ADF (front) scanning: Refer to Section 5-9-6.
ADF (back) scanning: Refer to Section 5-10-4.